For decades, a building's energy performance was measured solely by its operational consumption. Today, the energy embodied in materials — embodied energy — accounts for about a quarter of the non-renewable primary energy balance of a new low-energy apartment building, daily mobility included, and for most of the greenhouse gas emissions of most modern or renovated buildingsecobau (June 2025, § 1.3, p. 5): in most modern or renovated buildings, most GHG emissions arise at the construction stage. The quarter: SFOE 8719, p. 6 (42.0 of 158.9 kWh/m²·yr).Association ecobau — Bâtiments à faibles émissions de gaz à effet de serre — guide pour les maîtres d'ouvrages (état juin 2025, V1-0). This has become a central issue, and Geneva law now frames it: a low-carbon concept is required for permit applications filed from 1 January 2029, limit values to be met from 1 January 2034RECMC art. 4 para. 1–2 and art. 8 para. 1–2: low-carbon concept for permit applications filed from 1 January 2029, limit values for those filed from 1 January 2034.République et canton de Genève — Recueil systématique genevois — Règlement concernant l'empreinte carbone des matériaux de construction (RECMC), rsGE L 5 05.05.
Embodied energy (or incorporated energy) refers to all the energy required to produce a building: raw material extraction, industrial processing, transport, on-site installation, maintenance, replacement over the building's life, then demolition and end-of-life treatment.
It is expressed in non-renewable primary energy — historically in MJ/m² of energy reference area (SRE), or in kWh/m²·yr annualised over the building's standard service life (60 years per SIA 2032 technical guidelineMinergie, embodied energy calculation for the ECO add-on, v2023.2, sect. 1, p. 3: building service life set at 60 years; amortisation periods per technical guideline SIA 2032:2020.Minergie Suisse — Calcul de l'énergie grise et des émissions grises de gaz à effet de serre pour le complément ECO au label Minergie, version 2023.2). But the indicator now used by Geneva's legal framework is not energy: it is the embodied carbon, i.e. the balance of greenhouse gas emissions expressed in kg CO₂-eq/m²·yr.
Life Cycle Assessment (LCA) — or Analyse du Cycle de Vie (ACV) — is the standardised method for quantifying a building's environmental impact from "quarry to landfill". In Switzerland, the technical guideline SIA 2032 (life cycle inventory method) and the European standard EN 15978 structure the LCA into four main modules.
Geneva's regulatory calculation covers the manufacture of materials, their transport to site, their installation and their eventual disposal (RECMC, art. 1)RECMC art. 1 para. 1: the carbon footprint includes in particular emissions from manufacturing the materials, transporting them to site, installing them and their eventual disposal.République et canton de Genève — Recueil systématique genevois — Règlement concernant l'empreinte carbone des matériaux de construction (RECMC), rsGE L 5 05.05 — i.e. modules A1–A5 and C — and follows the principles of SIA 390/1:2025, whose “construction” domain also includes the replacement of components during use (B4)ecobau, June 2025, annex 1, p. 21, after SIA 390/1: construction covers manufacture and installation, replacement of components during use, and deconstruction and disposal.Association ecobau — Bâtiments à faibles émissions de gaz à effet de serre — guide pour les maîtres d'ouvrages (état juin 2025, V1-0). Module D stays outside the balance: neither SIA 390/1 nor the KBOB list credits negative emissions. SNBS, the Swiss Sustainable Building Standard, and DGNB, the German certification system for sustainable buildings, also include an LCA; both are whole-sustainability frameworks, not energy labels.
Embodied energy varies considerably depending on the material. The Swiss database KBOB (Koordinationskonferenz der Bau- und Liegenschaftsorgane der öffentlichen Bauherren)Official name on kbob.admin.ch: Koordinationskonferenz der Bau- und Liegenschaftsorgane der öffentlichen Bauherren — the Swiss public-sector building owners' coordination conference.Confédération suisse — kbob.admin.ch — Conférence de coordination des services de la construction et des immeubles des maîtres d'ouvrage publics KBOB publishes, with ecobau, the life cycle data list on which SIA 2032, Minergie and Geneva's RECMC rely. The chart below compares construction embodied-carbon target values for new housing by construction type, per m² of energy reference area (SRE)The RECMC uses neither "surface de référence énergétique" nor "SRE": its annex states limit values in kg CO2 eq./m2/an and refers the calculation to standard SIA 390/1:2025 (art. 3 para. 2, art. 5 para. 2).République et canton de Genève — Recueil systématique (silgeneve.ch) — Règlement concernant l'empreinte carbone des matériaux de construction (RECMC), rsGE L 5 05.05.
Early-design target values from the ecobau guide (June 2025, table 4) for the heated floor area of new housing, in kg CO₂-eq/m²·yr — the indicator enforceable in Geneva; each range covers high or low compactness. They are not measurements, and the guide does not distinguish insulation types. SIA 390/1 “construction” scope: manufacture and installation, replacements, deconstruction and disposal, annualised over 60 years, per m² SRE. In embodied energy, the Minergie-ECO limit values for new apartment buildings are 28 and 35 kWh/m²·yr, i.e. about 100 and 126 MJ/m²·yrMinergie, embodied energy calculation for the ECO add-on, v2023.2 (9.11.2023), sect. 4.2, p. 13: new apartment building, base limit values 28 (VL1) and 35 (VL2) kWh/m²·yr; × 3.6 = 100.8 and 126 MJ.Minergie Suisse — Calcul de l'énergie grise et des émissions grises de gaz à effet de serre pour le complément ECO au label Minergie, version 2023.2.
According to the SFOE, the structural shell accounts for about one third of embodied energySFOE, guide to embodied energy in new buildings, p. 12: "about one third" for the structural shell (group C), "one fifth each" for interior fit-out (G) and services (D); C, D and G offer the greatest potential.Office fédéral de l'énergie (OFEN) / SuisseEnergie — L'énergie grise dans les nouveaux bâtiments — Guide pour les professionnels, with building services and interior fit-out about one fifth each.
The canton of Geneva has embedded, in its loi sur les constructions et les installations diverses (Buildings and Miscellaneous Installations Act, LCI, of 14 April 1988, rsGE L 5 05)LCI, rsGE L 5 05, of 14 April 1988 (in force 11 June 1988), title IIIA “Empreinte carbone des matériaux de construction”, art. 117 and 118; consolidated text as at 22.10.2025.République et canton de Genève — Recueil systématique genevois — rsGE L 5 05 — Loi sur les constructions et les installations diverses (LCI), du 14 avril 1988, requirements that go beyond mere operational energy performance. Articles 117 and 118 form a complementary pair: one sets the rule for material selection, the other the method for measuring their carbon impact.
Calculating embodied energy rests on three complementary pillars: a standard and its methodological technical guideline (SIA 390/1 and SIA 2032), a database of material values (KBOB), and software tools that combine them.
The RECMC prescribes no software. For Minergie-ECO and SNBS, ecobau keeps the list of accredited tools — Enerweb, GREG, Lesosai, THERMO and vyzn among othersecobau, June 2025, annex 3, table 12, p. 31: Enerweb, Greg, Lesosai, THERMO, vyzn accredited; Ecotool, the Minergie tool and the SIA 2040 tool not accredited, not accepted for detailed Minergie-ECO or SNBS proof.Association ecobau — Bâtiments à faibles émissions de gaz à effet de serre — guide pour les maîtres d'ouvrages (état juin 2025, V1-0); Ecotool and the Minergie tool are free but do not count as detailed proof. PHPP, an operational-balance tool, is not on the list. In Switzerland it is the KBOB values that count.
Unlike operational energy, embodied energy cannot be offset after the fact: it is committed at the time of construction. Structuring decisions must therefore be made upstream, from the earliest sketches.
Solid wood (CLT, glulam), cellulose fibre, hemp, straw, rammed earth, raw earth bricks: per kilo, the KBOB list gives for example 1.05 kWh of embodied energy for cellulose fibre against 30 for EPS and PUR. At building scale the gap narrows sharply (see section 03). Wood also stores atmospheric carbon (sink effect). Local geo-sourced materials (stone, earth) reduce transport energy.
Reusing an existing beam or a concrete slab avoids most of the manufacturing embodied energy of a new component; the RECMC names reuse as a means of reducing the carbon footprint (art. 5 para. 3). Structural reuse (floors, framing, façades) is one of the most powerful levers.
Less material means less embodied energy. A compact form reduces envelope surface area. A structure sized precisely (accurate structural calculation, optimised sections) avoids over-consumption of concrete or steel. The principle of "building lean" is the first embodied-energy move, even before the choice of materials.
A durable material is replaced only once over 60 years instead of two or three — proportionally reducing its B4 impact. Moreover, a "demountable" design (mechanical fixings rather than adhesives, reversible assemblies) enables future reuse of components: this is circular architecture in practice.
Transport to site (module A4) is part of the carbon footprint under the RECMC (art. 1): it is a lever that can be acted on. Favouring certified regional timber (FSC/PEFC), insulation manufactured in Switzerland or neighbouring France, and local aggregates reduces this impact while supporting local supply chains.
Only certain labels go beyond operational energy performance to include embodied energy and the carbon balance of materials. The table below summarises the main certifications available in French-speaking Switzerland and neighbouring France. Passivhaus Classic and Geneva's HPE/THPE levels do not appear: they cover only operational energy (REn art. 12B/12C — rsGE L 2 30.01)HPE (REn art. 12B) and THPE (REn art. 12C) standards, rsGE L 2 30.01: they address operational energy performance, independently of LCI art. 117-118.République et canton de Genève — Recueil systématique (silgeneve.ch) — rsGE L 2 30.01 — Règlement d'application de la loi sur l'énergie (REn), du 31 août 1988, the embodied carbon of materials falling under LCI art. 117–118.
| Label | Embodied energy required | Standard / method | Remark |
|---|---|---|---|
| Minergie® / -P / -A and ECO add-on | ✓ Yes | SIA 2032:2020 + KBOB | Limit value for embodied emissions on every new build since the 2023 standards, and on major renovations (2026.1 label regulations, sect. 15)Minergie label regulations 2026.1, sect. 15: new builds and major renovations must meet an embodied-emissions limit value, calculated per SIA 2032:2020 and KBOB data 2009/1:2022; values in annex G.Minergie Suisse — Règlement des labels MINERGIE®/MINERGIE-P®/MINERGIE-A®, version 2026.1; the ECO add-on adds embodied-energy limit values and health/materials criteria |
| SNBS · DGNB | ✓ Yes — central | Each framework has its own LCA; SNBS: thresholds based on the Minergie-ECO limit values | Overall sustainability frameworks, not energy labels: LCA weighted into the score. |
| RE2020 (France) | ✓ Yes — Ic construction | Dynamic regulatory LCA (order of 4 August 2021) | Ic construction indicator (kg CO₂-eq/m², cumulative over the 50-year reference study period)Guide RE2020, September 2026 version (includes the decree of 18 March 2026), p. 29: Icconstruction_maxmoyen for apartment buildings — 740 kg CO₂-eq/m² (2022 to 2024), 650, 580 (2028 to 2030), 490 from 2031; 50-year reference study period (p. 10).Ministères Aménagement du territoire et Transition écologique / Cerema — Guide RE2020 — Réglementation environnementale des bâtiments neufs (version septembre 2026) with thresholds tightening in 2025, 2028 and then 2031 |
Is embodied energy mandatory in Geneva?
Not yet for a private project: the low-carbon concept applies to permit applications filed from 1 January 2029, the limit values to those filed from 1 January 2034; the canton complies from 2027 (RECMC art. 4 and 8). The principle is already in the law: LCI art. 117 requires limiting the embodied carbon of materials — priority to reuse, then to recycled or low-carbon-footprint materials — and art. 118 defines the method. The figures and the timetable come from the RECMC: see section 04. It covers new buildings within the scope of SIA 390/1 that require a building permit, outside the fast-track procedure, and major renovations: at least two categories substantially renovated, or one fully renovated (RECMC art. 1 para. 6 and 7)RECMC art. 1 para. 6: new building within the scope of SIA 390/1:2025, requiring a permit, outside the fast-track procedure; para. 7: substantial renovation of at least 2 categories or full renovation of one, heat generation excluded.République et canton de Genève — Recueil systématique genevois — Règlement concernant l'empreinte carbone des matériaux de construction (RECMC), rsGE L 5 05.05. At federal level, the Energy Act has required the cantons since 1 January 2025 to set embodied-energy limit values for new buildings and major renovations (EnA art. 45 para. 3 let. e)Energy Act art. 45 para. 3 let. e: the cantons issue provisions on embodied-energy limit values for new buildings and major renovations; letter in force since 1 January 2025 (AS 2024 648).Confédération suisse — Fedlex — RS 730.0 — Loi sur l'énergie (LEne), du 30 septembre 2016, état au 1er avril 2026.
Can concrete be kept while still reducing embodied energy?
Yes, several levers exist: low-clinker concrete (cement substituted with fly ash or blast furnace slag), recycled concrete for certain applications, optimised structural sections, and offsetting through the choice of bio-based insulation and low-embodied-energy finishes. A heavyweight building designed with high ambition can reach 6 to 6.5 kg CO₂-eq/m²·yr, the target value of a timber building of medium ambitionecobau, June 2025, table 4, p. 22, new housing: heavyweight, “low” target 6–6.5 kg CO₂-eq/m²·yr; timber, “medium” target 6–6.5.Association ecobau — Bâtiments à faibles émissions de gaz à effet de serre — guide pour les maîtres d'ouvrages (état juin 2025, V1-0).
At what project phase should this be addressed?
Embodied energy is essentially "won" or "lost" during the preliminary studies (EP) and preliminary design (APD) phases. A quick estimate based on a massing and a construction system is enough to guide the major choices. Waiting until the execution file to think about it means it is no longer possible to act on the decisions that really matter.
How can embodied energy be integrated into an architecture competition?
The brief can set an embodied-carbon criterion in kg CO₂-eq/m²·yr. At competition stage an element-based estimate is enough: technical guideline SIA 2032:2020 provides a calculation table for preliminary studies and preliminary design (annex D) and a list of common construction elements; ecobau gives target values by construction type to set the goal.
GenevaLCI art. 117 and 118 and the RECMC (rsGE L 5 05.05): reuse first, then recycled or low-footprint materials, with quantified limit values.
SwitzerlandSince 1 January 2025 the federal Energy Act has required the cantons to set embodied-energy limit values for new buildings and major renovations (art. 45 para. 3 let. e). SIA 390/1:2025 and the KBOB data are the reference; Minergie, Minergie-ECO, SNBS and DGNB take embodied energy into account, voluntarily.
Neighbouring FranceThe RE2020 requires a statutory life-cycle assessment for the new buildings it covers — housing since 2022, offices and schools since July 2022 — through the Ic construction indicator in kg CO₂-eq/m² over 50 years. Its method and scope differ from Geneva's: the two do not compare.